HV/LV Transformation and Distribution Solutions

Purpose-built transformers and low voltage distribution boards for grid-connected renewable energy and utility applications.

PRODUCT OVERVIEW

Complete HV/LV Packages — Designed Together

GreenBox supplies and engineers transformer and LVDB (Low Voltage Distribution Board) solutions for renewable energy grid connection points. From pad-mount transformers for solar farm POCs to LVDBs for large commercial systems — we handle design, procurement, compliance and documentation.

 

By designing the transformer and LVDB together, we ensure correct protection discrimination, coordinated metering, and a single documentation package — eliminating the interface risk that arises when separate suppliers are responsible for each element.

 

All transformers are supplied with AS60076 test certificates from accredited manufacturers — accepted by Australian DNSPs and asset managers for grid connection approval.

Technical Specifications
Transformer Ratings
25kVA to 2500kVA
Primary Voltage
11kV / 22kV / 33kV
Secondary Voltage
400V (3Ph, 4-wire)
Cooling
ONAN / ONAF
Vector Group
Dyn11
Standards
AS60076
IP Rating
IP44 minimum
LVDB Current Rating
Up to 2500A
LVDB Standard
AS/NZS 61439

NOTE
GreenBox manages transformer procurement from accredited manufacturers and coordinates delivery with in-house LVDB fabrication — providing a single-supplier package from specification to commissioning.

KEY FEATURES

A Complete Substation Package

Full Design Package

Complete engineering design, protection coordination, single-line diagrams and compliance documentation for both the transformer and LVDB assembly.

HV to LV Step-Down

11kV, 22kV and 33kV primary options cover all Australian DNSP distribution voltages for renewable energy and commercial grid connections.

ONAN & ONAF Options

Oil Natural Air Natural (ONAN) and Oil Natural Air Forced (ONAF) cooling configurations available depending on kVA rating and site constraints.

Custom LVDB Integration

Low voltage distribution boards designed and coordinated alongside the transformer — ensuring correct protection discrimination and metering from the outset.

AS60076 Compliant

All transformers are supplied with AS60076 test certificates from accredited manufacturers — accepted by Australian DNSPs and asset managers.

Complete Documentation

Factory test certificates, routine and type test reports, nameplate data, AS60076 certificates and installation manuals supplied with every transformer.

APPLICATIONS

Deployed Across Every Grid Connection Type

Solar Farm Grid Connection (POC)

Step-up and step-down transformers for solar farm point of connection — sized and configured to DNSP technical requirements with coordinated LVDB protection.

Large Commercial Rooftop

Pad-mount transformers for large commercial rooftop systems connecting at 11kV or 22kV — with LVDB distribution for inverter cluster connections.

Battery Energy Storage

Transformer and LVDB packages for utility-scale and commercial BESS grid connections — coordinated with inverter protection and DNSP requirements.

Industrial Power Supply

Distribution transformers for industrial facilities connecting at HV — with custom LVDB distributions for motor, HVAC and process loads.

Utility Substations

Complete substation packages including transformer, LVDB, protection relays and metering — for utility network extensions and customer-owned substations.

BENEFITS

Why Source Through GreenBox

Single-Supplier Solution

Transformer and LVDB designed and coordinated together — eliminating the interface risk and responsibility gaps that arise when separate suppliers design each element.

Faster Project Delivery

Our established relationships with accredited transformer manufacturers and LVDB fabricators enable competitive lead times and project scheduling certainty.

DNSP-Ready Documentation

AS60076 test certificates, single-line diagrams and protection coordination studies are supplied in formats accepted by Australian DNSPs for grid connection approval.

FAQ

Transformer Questions

Our engineering team can assist with substation specification and DNSP documentation requirements for your project.
Do you supply transformers directly or coordinate procurement?
GreenBox manages the full supply — including specification, procurement from accredited Australian and international manufacturers, and coordination of delivery. We do not manufacture transformers, but we manage every aspect of the supply process and provide the complete documentation package.
Our standard range covers 25kVA to 2500kVA with primary voltages of 11kV, 22kV and 33kV — covering all standard Australian DNSP distribution voltages. Non-standard voltage ratings are available on request.
Yes. GreenBox designs and coordinates the LVDB alongside the transformer specification — ensuring protection discrimination, metering and busbar ratings are correctly matched. The LVDB is manufactured at our Clayton South facility and supplied with the transformer as a coordinated package.
The package includes AS60076 routine and type test reports, nameplate specifications, single-line diagrams, protection coordination study, LVDB wiring schedules, AS/NZS 61439 test certificate, and an installation and maintenance manual.
Standard transformer packages typically require 10–16 weeks. LVDB fabrication is typically 4–6 weeks and is coordinated to align with transformer delivery. Project-specific scheduling is confirmed at the time of order.
Scroll to Top